Pawel Kisiel
- Total activity 38
- Last activity
- Member since
- Following 0 users
- Followed by 0 users
- Votes 0
- Subscriptions 21
Activity overview
Latest activity by Pawel Kisiel-
Pawel Kisiel created an article,
Error when exporting or saving data to Spotfire Library: Could not save data file
Keywords: Tibco Spotfire, Spotfire Analyst, SQL Server, Information Designer Details: In trying to export data table with 1.5M+ rows from analysis file into Library as SBDF file then encounterin...
-
Pawel Kisiel created an article,
How to enabling Kerberos debug logging in Tibco Spotfire
Troubleshooting of Kerberos authentication issues in Spotfire can be enhanced by enabling Kerberos debug logging as follows: Export and open the configuration.xml file from <server installation di...
-
Pawel Kisiel created an article,
Spotfire Information Link fails with error "Invalid relational operator" when IN clause size is greater than 1000
Cause: According to Spotfire data source XML template specification, max-in-clause-size defines the maximum size of an SQL IN clause, causing larger lists to be split into several IN clauses that a...
-
Pawel Kisiel created an article,
How to retrieve a list of all Spotfire users, a list of licenses and a list of groups
A list of all Spotfire users can be generated using Spotfire Server administration command 'list-users':https://docs.tibco.com/pub/spotfire_server/10.10.2/doc/html/TIB_sfire_server_tsas_admin_help/...
-
Pawel Kisiel created an article,
How to update Spotfire Server IP address
If Spotfire Server machine's IP address is changed, then the following configuration update is required: 1. Stop all Spotfire Servers and Node Managers (assuming this is a cluster with multiple s...
-
Pawel Kisiel created an article,
How to upgrade PerkinElmer Spotfire Lead Discovery Biotech Bundle for AWS
Upgrade process involves deploying a new Spotfire Lead Discovery Biotech Bundle environment and then migrating users, groups and analysis files from previous environment. The process is not an in-p...
-
Pawel Kisiel created an article,
What is the purpose of siautils.exe (or sldutils.exe) in Signals Inventa and Signals Lead Discovery?
Executables siautils-<version>.exe (formerly sldutils-<version>.exe) is a command line utility that helps migrate data from previous versions of Signals Lead Discovery to the latest version of Sign...
-
Pawel Kisiel created an article,
Is there a way to create custom preferences in Tibco Spotfire?
It is possible to create custom preferences in Spotfire and make them available in Administration Manager. This can be done using Spotfire Analyst API class CustomPreference: https://docs.tibco.com...
-
Pawel Kisiel created an article,
Spotfire Server Troubleshooting Bundle doesn't include logs from some nodes
When Spotfire Server global troubleshooting bundle is requested, on the 'Monitoring&Diagnostics' page, the downloaded zip file sometimes doesn't contain any log files from some node machines in Spo...
-
Pawel Kisiel created an article,
Spotfire Analyst error "The remote server returned an error: (405) Method Not Allowed."
This article outlines troubleshooting steps for Spotfire Analyst error 405 "Method Not Allowed" and provides a solution to one possible cause of this issue. The error occurs when end users try to l...