Latest activity by Pawel Kisiel-
Pawel Kisiel created an article,
All Spotfire users are not able to login in web browser, but everyone is able to login in Analyst client
Keywords: Spotfire Server, authentication, SameSite cookie, Kerberos, blank page There could be numerous reasons why end users are not able to login to Spotfire Server. This article addresses only ...
-
Pawel Kisiel created an article,
Does setting "X-Frame-Options" to SAMEORIGIN on Spotfire Server have any impact on web pages that use Spotfire Javascript API or embedded analysis iframe?
Keywords: Spotfire Server, X-Frame-Options, SAMEORIGIN, clickjacking Answer: With configuration properties "security.x-frame-options.enabled" set to "true" and "security.x-frame-options.directive" ...
-
Pawel Kisiel created an article,
How to add a new ingress definition in Signals Inventa
Keywords: Signals Inventa, Signals Data Factory Details: In Signals Inventa, multiple URLs can be configured to point to the same Signals Data Factory system. This is achieved by configuring mult...
-
Pawel Kisiel created an article,
Error when exporting or saving data to Spotfire Library: Could not save data file
Keywords: Tibco Spotfire, Spotfire Analyst, SQL Server, Information Designer Details: In trying to export data table with 1.5M+ rows from analysis file into Library as SBDF file then encounterin...
-
Pawel Kisiel created an article,
How to enabling Kerberos debug logging in Tibco Spotfire
Troubleshooting of Kerberos authentication issues in Spotfire can be enhanced by enabling Kerberos debug logging as follows: Export and open the configuration.xml file from <server installation di...
-
Pawel Kisiel created an article,
Spotfire Information Link fails with error "Invalid relational operator" when IN clause size is greater than 1000
Cause: According to Spotfire data source XML template specification, max-in-clause-size defines the maximum size of an SQL IN clause, causing larger lists to be split into several IN clauses that a...
-
Pawel Kisiel created an article,
How to retrieve a list of all Spotfire users, a list of licenses and a list of groups
A list of all Spotfire users can be generated using Spotfire Server administration command 'list-users':https://docs.tibco.com/pub/spotfire_server/10.10.2/doc/html/TIB_sfire_server_tsas_admin_help/...
-
Pawel Kisiel created an article,
How to update Spotfire Server IP address
If Spotfire Server machine's IP address is changed, then the following configuration update is required: 1. Stop all Spotfire Servers and Node Managers (assuming this is a cluster with multiple s...
-
Pawel Kisiel created an article,
How to upgrade PerkinElmer Spotfire Lead Discovery Biotech Bundle for AWS
Upgrade process involves deploying a new Spotfire Lead Discovery Biotech Bundle environment and then migrating users, groups and analysis files from previous environment. The process is not an in-p...
-
Pawel Kisiel created an article,
What is the purpose of siautils.exe (or sldutils.exe) in Signals Inventa and Signals Lead Discovery?